WEBVTT 00:00:05.480 --> 00:00:07.800 Welcome to this guide, 00:00:07.800 --> 00:00:09.680 which sets out the correct use 00:00:09.680 --> 00:00:13.640 of the Kefdensis single-use pre-filled syringe. 00:00:14.400 --> 00:00:17.400 The syringe is made up of the following parts: 00:00:17.480 --> 00:00:22.320 grey needle cap, needle, syringe barrel, 00:00:22.320 --> 00:00:27.000 transparent safety guard, finger grip and plunger. 00:00:28.000 --> 00:00:29.200 After use 00:00:29.200 --> 00:00:31.000 the needle retracts, 00:00:31.000 --> 00:00:33.360 the safety spring activates 00:00:33.360 --> 00:00:34.960 and the plunger locks. 00:00:37.120 --> 00:00:43.240 Kefdensis should be stored in a refrigerator at 2 to 8 °C. 00:00:43.840 --> 00:00:45.480 Do not freeze. 00:00:45.680 --> 00:00:49.040 Keep it in the outer carton to protect from light, 00:00:49.360 --> 00:00:52.560 and keep it out of the sight and reach of children. 00:00:52.960 --> 00:00:57.240 First, take Kefdensis out of the refrigerator. 00:00:57.640 --> 00:01:00.040 For a more comfortable injection, 00:01:00.040 --> 00:01:05.720 leave the pre-filled syringe at room temperature (up to 25 °C) 00:01:05.720 --> 00:01:09.080 for about 30 minutes before injecting. 00:01:09.880 --> 00:01:16.800 Do not try to warm the syringe by using a heat source such as hot water or a microwave, 00:01:16.800 --> 00:01:20.400 and do not expose it to direct sunlight. 00:01:20.840 --> 00:01:27.440 Remove the pre-filled syringe from the package by taking hold of the pre-filled syringe safety guard. 00:01:27.920 --> 00:01:30.520 Do not shake the pre-filled syringe. 00:01:30.800 --> 00:01:33.600 Do not hold or pull the plunger. 00:01:33.720 --> 00:01:39.200 Do not touch or remove the grey needle cap until you are ready to inject. 00:01:39.520 --> 00:01:44.800 The Kefdensis pre-filled syringe is for subcutaneous use only. 00:01:45.480 --> 00:01:48.520 Check the expiry date on the label. 00:01:48.520 --> 00:01:51.640 Do not use if the product has expired. 00:01:52.040 --> 00:01:57.880 Kefdensis may be stored at room temperature (up to 25 °C) 00:01:57.880 --> 00:02:01.560 for up to 30 days in the original carton. 00:02:01.560 --> 00:02:05.080 It must be used within this 30-day period, 00:02:05.080 --> 00:02:08.360 without exceeding the original expiry date. 00:02:09.640 --> 00:02:14.360 Lay out everything you will need on a clean, well-lit surface: 00:02:15.160 --> 00:02:17.760 the new pre-filled syringe, 00:02:17.760 --> 00:02:19.680 an alcohol wipe, 00:02:20.000 --> 00:02:22.760 a cotton ball or gauze pad, 00:02:22.760 --> 00:02:24.200 a plaster, 00:02:24.200 --> 00:02:26.600 and a sharps disposal container. 00:02:27.200 --> 00:02:32.120 Do not use the pre-filled syringe and contact your healthcare provider 00:02:32.120 --> 00:02:35.920 if it has been shaken, dropped on a hard surface, 00:02:35.920 --> 00:02:40.040 if any part of the syringe appears cracked or broken, 00:02:40.040 --> 00:02:44.720 or if the grey needle cap is missing or not securely attached. 00:02:45.920 --> 00:02:49.160 Wash your hands thoroughly with soap and water. 00:02:50.920 --> 00:02:54.440 The best places to inject are around the belly, 00:02:54.440 --> 00:02:58.000 at least 5 cm away from the belly button, 00:02:58.000 --> 00:03:00.320 or the upper part of the thigh. 00:03:00.560 --> 00:03:03.560 If someone else is giving you the injection, 00:03:03.560 --> 00:03:07.880 you can also use the outer area of the upper arm. 00:03:08.480 --> 00:03:13.680 Clean the injection site with an alcohol wipe and let the skin dry. 00:03:13.680 --> 00:03:17.200 Do not touch the injection site before injecting. 00:03:17.920 --> 00:03:21.440 Do not inject into areas where the skin is tender, 00:03:21.440 --> 00:03:25.240 bruised, red, hard, scarred, 00:03:25.240 --> 00:03:26.960 or has stretch marks. 00:03:28.160 --> 00:03:32.000 Hold the body of the pre-filled syringe in one hand. 00:03:32.000 --> 00:03:35.120 With the needle pointing away from your body, 00:03:35.120 --> 00:03:40.160 carefully pull the grey needle cap straight off and dispose of it. 00:03:42.360 --> 00:03:48.640 Use the other hand to pinch the injection site to create a firm surface, 00:03:48.640 --> 00:03:51.960 and keep the skin pinched when injecting. 00:03:52.920 --> 00:03:58.760 Insert the needle into the pinched skin at around a 45-degree angle. 00:04:00.200 --> 00:04:07.480 Use your thumb to push the plunger with slow and constant pressure all the way down. 00:04:09.480 --> 00:04:11.640 Release your thumb, 00:04:14.080 --> 00:04:17.320 then lift the syringe off the skin. 00:04:17.640 --> 00:04:19.680 After releasing the plunger, 00:04:19.680 --> 00:04:25.160 the pre-filled syringe safety guard will safely cover the injection needle. 00:04:25.680 --> 00:04:30.320 After completing the injection, examine the injection site. 00:04:30.320 --> 00:04:37.160 If there is blood, press a cotton ball or gauze pad on the injection site without rubbing. 00:04:37.360 --> 00:04:39.760 Apply a plaster if needed. 00:04:40.760 --> 00:04:45.080 Discard the used pre-filled syringe and other supplies 00:04:45.080 --> 00:04:49.560 in a sharps disposal container straight away after use, 00:04:49.560 --> 00:04:52.320 in accordance with local requirements.